• DocumentCode
    405040
  • Title

    Effect of motor speed on the optimum operating point of direct torque controlled induction motor

  • Author

    Kaboli, Sliahriyar ; Zolghadri, Mohaminad Reza

  • Author_Institution
    Dept. of Electr. Eng., Sharif Univ. of Technol., Tehran, Iran
  • Volume
    2
  • fYear
    2003
  • fDate
    9-11 Nov. 2003
  • Firstpage
    619
  • Abstract
    The flux and torque hysteresis bands are the only gains to be adjusted in direct torque control (DTC). The torque ripple and harmonic loss of motor and switching loss of inverter are greatly influenced by them. In this paper the effects of flux and torque hysteresis bands on inverter switching loss, harmonic loss and torque ripple of induction motor are investigated through a cost function. Minimizing this cost function leads to the optimum value of the hysteresis bands of torque and flux controllers. The effect of motor speed on cost function is also investigated.
  • Keywords
    induction motors; machine control; magnetic flux; magnetic hysteresis; power conversion harmonics; switching convertors; torque control; direct torque control; flux control; flux hysteresis; induction motor; inverter switching loss; motor harmonic loss; motor speed; torque hysteresis; torque ripple; Cost function; Current measurement; Hysteresis motors; Induction motors; Inverters; Iron; Stators; Switching loss; Torque control; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2003. ICEMS 2003. Sixth International Conference on
  • Conference_Location
    Beijing, China
  • Print_ISBN
    7-5062-6210-X
  • Type

    conf

  • Filename
    1274122