DocumentCode :
405103
Title :
Fault identification method of rotor inter turn short-circuit using stator winding detection
Author :
Yonggang, Li ; Heming, Li ; Hua, Zhao ; Shuting, Wan
Author_Institution :
North China Electr. Power Univ., Baoding, China
Volume :
2
fYear :
2003
fDate :
9-11 Nov. 2003
Firstpage :
856
Abstract :
In this paper, the electromagnetic characteristics on rotor windings inter turn short-circuit of steam generator has been analyzed and calculated. The phenomenon, which the variation of main magnetic field of rotor windings is more apparent than the stray magnetic field when the rotor winding inter turn short-circuit happens, has been found. Using the stator winding as the fault detection winding, the corresponding relationships between the faults levels of rotor winding inter turn short-circuit and the effective magnetic field loss is established. The relevant verification has been carried using the dynamic simulative experimental units, and the result coincides with the theory deduction.
Keywords :
electric generators; electromagnetic fields; fault diagnosis; magnetic fields; rotors; short-circuit currents; stators; dynamic simulation; electromagnetic characteristics; fault detection winding; fault identification method; magnetic field; rotor inter turn short-circuit; rotor windings; stator winding detection; steam generator; Air gaps; Circuit faults; Coils; Fault detection; Fault diagnosis; Magnetic analysis; Magnetic fields; Magnetic flux; Rotors; Stator windings;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2003. ICEMS 2003. Sixth International Conference on
Conference_Location :
Beijing, China
Print_ISBN :
7-5062-6210-X
Type :
conf
Filename :
1274185