DocumentCode :
405950
Title :
Angular dose variations from 4- to 6-MV rod-pinch diode experiments on the ASTERIX pulsed-power generator
Author :
Swanekamp, S.B. ; Allen, R.J. ; Commisso, R.J. ; Cooperstein, G. ; Mosher, D. ; Young, F.C. ; Vermare, C. ; Delvaux, J. ; Horde, Y. ; Merle, E. ; Nicolas, R. ; Nore, D. ; Pierret, O. ; Rosol, Y.R. ; Tailleur, Y. ; Veron, L. ; Bayol, F. ; Garrigues, A. ; D
Author_Institution :
Div. of Plasma Phys., Naval Res. Lab., Washington, DC, USA
Volume :
1
fYear :
2003
fDate :
15-18 June 2003
Firstpage :
483
Abstract :
The angular distribution of radiation from a rod-pinch diode is examined with coupled PIC-Monte-Carlo simulations using the LSP code (D.R. Welch, et al., 2001) and compared with angular dose measurements on the ASTERIX pulsed-power generator. For the 4- to 6-MV voltage range accessible in the experiments, both the measured and simulated doses at 1 m were 25 to 38 rad-LiF in the forward direction (0/spl deg/). The calculated dose at 90/spl deg/ is 1.2-1.8 times larger than the forward-directed dose depending on both the voltage and rod diameter. This is also in agreement with the measured angular variation (F.C. Young, et al.,). At 6 MV, the simulations show that the dose near 180/spl deg/ is more than twice the forward-directed dose. At these high voltages, electrons approach the anode rod primarily at angles close to 180/spl deg/ resulting in peak radiation in the backward direction. This suggests that negative polarity should be considered for voltages at or above 6 MV to maximize the extracted dose. Simulations show that the 0/spl deg/ dose is higher with tapered rods and increases with rod diameter. Simulations at 10 MV show that the dose near 180/spl deg/ is more than ten times higher than the 0/spl deg/ dose. At 10 MV, the dose near 180/spl deg/ at 1 m from a 2-mm diameter, blunt rod is calculated to be /spl sim/800 Rad (LiF).
Keywords :
Monte Carlo methods; angular measurement; lithium compounds; p-i-n diodes; pulse generators; thermoluminescent dosimeters; 10 MV; 4 MV; 6 MV; ASTERIX pulsed-power generator; LSP code; LiF; PIC-Monte-Carlo simulation; angular dose measurement; angular variation measurement; backward direction; blunt rod; forward-directed dose; radiation angular distribution; rod-pinch diode; Anodes; Cathodes; Diodes; Electrons; Gold; Laboratories; Pulse generation; Pulse measurements; Tungsten; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 2003. Digest of Technical Papers. PPC-2003. 14th IEEE International
Conference_Location :
Dallas, TX, USA
Print_ISBN :
0-7803-7915-2
Type :
conf
DOI :
10.1109/PPC.2003.1277756
Filename :
1277756
Link To Document :
بازگشت