DocumentCode :
406059
Title :
Non-contact ultrasonic imaging for post-tensioned bridges to investigate corrosion and void status
Author :
Sinha, Sunil K. ; Schokker, Andrea J. ; Iyer, S. Rama
Author_Institution :
Dept. of Civil & Env. Eng., Pennsylvania State Univ., University Park, PA, USA
Volume :
1
fYear :
2003
fDate :
22-24 Oct. 2003
Firstpage :
487
Abstract :
Corrosion of the nation´s transportation infrastructure is a widespread and costly problem. Recent corrosion problems in post-tensioned bridge structures have increased the need for a reliable method for determining grout voids and level of corrosion in post-tensioned tendons. Corrosion monitoring techniques such as half-cell potential and corrosion rate measurements face problems when used in this type of structure and standard NDE (nondestructive evaluation) methods such as impact-echo have also encountered problems. This study begins the evaluation of a method called C-Scan ultrasonic imaging to evaluate grouted post-tensioned tendons. While this paper focuses on post-tensioning applications, the C-Scan technique may be valuable for investigation of any type of reinforced concrete structure.
Keywords :
bridges (structures); corrosion testing; structural engineering; ultrasonic imaging; ultrasonic materials testing; voids (solid); C-Scan ultrasonic imaging; corrosion monitoring; corrosion problems; corrosion rate measurements; grout voids; half-cell potential; non-contact ultrasonic imaging; nondestructive evaluation; post-tensioned bridges; post-tensioned tendons; post-tensioning applications; reinforced concrete structure; transportation infrastructure; Bridges; Concrete; Corrosion; Ducts; Inspection; Protection; Steel; Structural beams; Tendons; Ultrasonic imaging;
fLanguage :
English
Publisher :