  • Abstract
    Independent component analysis (ICA) along with a differential pulse-code modulation (DPCM) system has been used for secure transmission of medical images. The advantage of this approach is the ability to compress images that will be transmitted securely. The combined DPCM-ICA system can be designed with varying levels of quantization, however, image quality is sacrificed for low quantization levels.
  • Keywords
    data compression; differential pulse code modulation; image coding; independent component analysis; medical image processing; quantisation (signal); security of data; telemedicine; DPCM; ICA; differential pulse-code modulation; image compression; independent component analysis; quantization; secure medical-image transmission; Biomedical imaging; Image analysis; Image coding; Image communication; Independent component analysis; Modulation coding; Principal component analysis; Pulse modulation; Quantization; Source separation;