DocumentCode
406710
Title
The control technique of three-phase voltage-source inverter output waveform based on internal model theory
Author
Kong, Xuejuan ; Wang, Jingjiang ; Peng, Li ; Kang, Yong ; Cheng, Jian
Author_Institution
Huazhong Univ. of Sci. & Technol., Wuhan, China
Volume
1
fYear
2003
fDate
2-6 Nov. 2003
Firstpage
788
Abstract
CVCF inverters are usually applied in critical situations, whose quality of output waveform is one of the most important aspects in evaluating its performance. This paper analyses the feasibility of the three-phase inverters´ output waveform control scheme based on internal model theory in rotating frame. One scheme is present which is the combination of instantaneous feedback control internal model restraining fundamental component disturbance and repetitive control internal model restraining harmonic component disturbance and asymmetrical disturbance. The experiments verify the scheme can work well. Fast response, highly accurate steady output and less distorted waveform is gained.
Keywords
feedback; invertors; power system control; waveform analysis; asymmetrical disturbance; constant voltage constant frequency inverters; fundamental component disturbance; harmonic component disturbance; instantaneous feedback control; internal model theory; inverter output waveform; repetitive control; rotating frame; three phase voltage-source inverter; Communication system control; Communication systems; Feedback control; Frequency; Inverters; Medical control systems; Military equipment; Power system modeling; Power system reliability; Voltage control;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics Society, 2003. IECON '03. The 29th Annual Conference of the IEEE
Print_ISBN
0-7803-7906-3
Type
conf
DOI
10.1109/IECON.2003.1280083
Filename
1280083
Link To Document