• DocumentCode
    406965
  • Title

    Feasibility test of prospective tracking of respiration signals for breathing compensated or gated radiotherapy

  • Author

    Liu, Haisong ; Yu, Yan ; Schell, Michael ; O´Dell, Walter ; Okunieff, Paul

  • Author_Institution
    Dept. of Radiat. Oncology, Rochester Univ., NY, USA
  • Volume
    3
  • fYear
    2003
  • fDate
    17-21 Sept. 2003
  • Firstpage
    2788
  • Abstract
    Motion compensation radiotherapy systems are currently available. Signals representing moving targets can be obtained from either real-time X-ray images of implanted markers near the target or external respiration sensors. However, a time lag exists between the motion signal acquisition and action execution (moving the robotic arm). This time lag has been estimated as 0.3 s, and a typical respiratory velocity of 2∼4 mm/sec results in a systematic position lag between 1 and 2 mm. In this study, the feasibility of prospective tracking of respiration signal based on autoregressive (AR) model was tested to compensate this time lag. Free breathing motion signals were acquired by an electromagnetic 3D position measurement system. The software for signal acquisition and AR model computation was developed as a visual C++ application. The signals were obtained at a frequency of 3 Hz. Original respiratory signal of T seconds (variable) was used to compute the AR model parameters. The model order was also variable. The model was updated every T seconds. The same model was used for T seconds while the input data was updated with the actual signals. The predicted positions were computed and the errors to the actual positions were computed. The position errors allowing for time lag were computed through shifting the motion signal by one time unit (∼0.33 seconds). Different methods to compute the AR model coefficients were tested, among which the Burg´s method has shown slightly better error reduction capability. In a typical test case, the mean absolute error was reduced from 0.8 mm to 0.25 mm for a respiratory signal of 1 min.
  • Keywords
    measurement errors; motion compensation; physiological models; pneumodynamics; position measurement; radiation therapy; 3 Hz; Burg method; autoregressive model; breathing compensated radiotherapy; breathing gated radiotherapy; breathing motion signals; electromagnetic 3D position measurement system; feasibility test; mean absolute error; position errors; prospective tracking; respiration signals; Application software; Computational modeling; Image sensors; Motion compensation; Position measurement; Robot sensing systems; Software systems; Target tracking; Testing; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2003. Proceedings of the 25th Annual International Conference of the IEEE
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-7789-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2003.1280496
  • Filename
    1280496