Title :
Common-mode noise source and its passive cancellation in full-bridge resonant converter
Author :
Borage, Mangesh ; Tiwari, Sunil ; Kotaiah, S.
Author_Institution :
Power Supplies Div., Centre for Adv. Technol., Indore, India
Abstract :
In this paper the results of systematic investigation into identification of dominant source of CM noise generation in a full bridge resonant converter are presented. It is shown that a small mismatch in an apparently symmetrical circuit can result in large CM injection. Mathematical analysis to predict the CM current injection is presented and is validated using SPICE simulation. For cancellation of dominant CM injection simple passive techniques are suggested. Experimental results on 18 kW LCC resonant magnet power supply for INDUS-2 are presented to demonstrate the effectiveness of proposed passive techniques.
Keywords :
electromagnetic interference; passive networks; resonant power convertors; 18 kW; CM injection; CM noise generation; INDUS-2; LCC resonant magnet power supply; SPICE simulation; common-mode noise source; current injection; full-bridge resonant converter; mathematical analysis; passive cancellation; passive techniques; symmetrical circuit; Analytical models; Bridge circuits; Circuit noise; Circuit simulation; Mathematical analysis; Noise cancellation; Noise generators; Predictive models; Resonance; SPICE;
Conference_Titel :
Electromagnetic Interference and Compatibility, 2003. INCEMIC 2003. 8th International Conference on
Print_ISBN :
81-900652-1-1
DOI :
10.1109/ICEMIC.2003.1287744