Abstract :
We propose a new extraction scheme with a massless septum magnet in FFAG accelerator, with which the DC beam can be extracted. The system consists of a combination of massless and ordinary septa without kickers. After passing through the massless septum, the beam tail is stretched by the field gradient of the massless septum magnet, and that can be extracted with an ordinary septum. From the result of the tracking simulation, the principle of the extraction scheme is verified. The result of the performance test of the massless septum indicates that the magnet works well as designed, and this scheme is feasible.
Keywords :
accelerator magnets; particle beam extraction; synchrotrons; DC beam; FFAG accelerator; beam extraction; beam tail; extraction scheme; massless septum magnet; tracking simulation; Acceleration; Accelerator magnets; Magnetic resonance; Magnetic separation; Magnetosphere; Particle beams; Protons; Synchrotrons; Tail; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
ISSN :
1063-3928
Print_ISBN :
0-7803-7738-9
Type :
conf
DOI :
10.1109/PAC.2003.1288634
Filename :
1288634
Link To Document :
بازگشت