• DocumentCode
    408916
  • Title

    Beam based measurements of hysteresis effects in Fermilab Main Injector magnets

  • Author

    Brown, B.C. ; Capista, D.P.

  • Author_Institution
    Fermi Nat. Accel. Lab., USA
  • Volume
    4
  • fYear
    2003
  • fDate
    12-16 May 2003
  • Firstpage
    2165
  • Abstract
    Operation of the Fermilab Main Injector is sensitive to magnetic field differences due to hysteretic effects. Measurements using the beam are reported with various current ramps. This will provide magnetic field information for accelerator operations with better ramp control than is available from magnet test facility data. This makes possible improved low field reproducibility with mixed 120 GeV and 150 GeV operation of the Main Injector.
  • Keywords
    accelerator magnets; hysteresis; particle beam diagnostics; proton accelerators; synchrotrons; Fermilab Main Injector magnets; accelerator operations; beam based measurements; current ramps; hysteretic effects; magnet test facility data; magnetic field differences; Acceleration; Accelerator magnets; Current measurement; Magnetic field measurement; Magnetic hysteresis; Power measurement; Power supplies; Production; Protons; Test facilities;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
  • ISSN
    1063-3928
  • Print_ISBN
    0-7803-7738-9
  • Type

    conf

  • DOI
    10.1109/PAC.2003.1289053
  • Filename
    1289053