DocumentCode
409033
Title
A second beam-diagnostic beamline for the Advanced Light Source
Author
Sannibale, E. ; Baum, D. ; Kelez, N. ; Scarvie, T. ; Holldack, K.
Author_Institution
LBNL, Berkeley, CA, USA
Volume
4
fYear
2003
fDate
12-16 May 2003
Firstpage
2527
Abstract
A second beamline, BL 7.2, completely dedicated to beam diagnostics is being installed at the Advanced Light Source (ALS). The design has been optimized for the measurement of the momentum spread and emittance of the stored beam in combination with the existing diagnostic beamline, BL 3.1. A detailed analysis of the experimental error has allowed the definition of the system parameters. The obtained requirements found a good matching with a simple and reliable system based on the detection of X-ray synchrotron radiation (SR) through a pinhole system. The actual beamline, which also includes a port for visible and infrared SR as well as an X-ray beam position monitor (BPM), is mainly based on the design of two similar diagnostic beamlines at BESSY II. This approach allowed a significant saving in time, cost and engineering effort. The design criteria, including a summary of the experimental error analysis, as well as a brief description of the beamline are presented.
Keywords
X-ray apparatus; electron accelerators; particle beam diagnostics; storage rings; synchrotron radiation; ALS; Advanced Light Source; BESSY II; X-ray beam position monitor; X-ray synchrotron radiation; diagnostic beamline; infrared synchrotron radiation; momentum spread; pinhole system; visible synchrotron radiation; Costs; Design optimization; Infrared surveillance; Light sources; Monitoring; Radiation detectors; Strontium; Synchrotron radiation; X-ray detection; X-ray detectors;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
ISSN
1063-3928
Print_ISBN
0-7803-7738-9
Type
conf
DOI
10.1109/PAC.2003.1289176
Filename
1289176
Link To Document