• DocumentCode
    409036
  • Title

    Progress on a Smith-Purcell radiation bunch length

  • Author

    Korbly, S.E. ; Kesar, A.S. ; Shapiro, M.A. ; Temkin, R.J.

  • Author_Institution
    Plasma Sci. & Fusion Center, MIT, Cambridge, MA, USA
  • Volume
    4
  • fYear
    2003
  • fDate
    12-16 May 2003
  • Firstpage
    2536
  • Abstract
    A Smith-Purcell radiation diagnostic to measure the microbunch length of a 20 MeV, 17 GHz electron bunch train is being implemented at MIT. The bunch length can be determined by measuring the frequency and angular distribution of the emitted radiation. The beam is produced by a 17 GHz, 50 MeV/m traveling wave accelerator built by Haimson Research Corporation (HRC). The high operating frequency of this accelerator allows for the production of ultrashort bunches of about 180 femtoseconds. At this time we are assembling the experiment and we will present an update on the progress.
  • Keywords
    electron accelerators; particle beam bunching; particle beam diagnostics; Haimson Research Corporation; MIT; Smith-Purcell radiation diagnostic; angular distribution; electron bunch train; emitted radiation; frequency distribution; microbunch length; traveling wave accelerator; ultrashort bunches; Cameras; Electron beams; Lasers and electrooptics; Length measurement; Particle beams; Particle scattering; Plasma measurements; Radio frequency; Surface emitting lasers; X-ray lasers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
  • ISSN
    1063-3928
  • Print_ISBN
    0-7803-7738-9
  • Type

    conf

  • DOI
    10.1109/PAC.2003.1289179
  • Filename
    1289179