• DocumentCode
    409087
  • Title

    Observation of coherent microwave transition radiation in the APS linac

  • Author

    Decker, G. ; Sun, X.

  • Author_Institution
    Argonne Nat. Lab., IL, USA
  • Volume
    4
  • fYear
    2003
  • fDate
    12-16 May 2003
  • Firstpage
    2688
  • Abstract
    The APS injector includes a conventional S-band linear accelerator with three separate electron sources. Two electron guns are used as primary and secondary sources for injection into the APS 7-GeV storage ring, while a separate laser photocathode gun is available for free-electron laser (FEL) research. We report here the results of the dependence of 30-GHz coherent microwave transition radiation on electron bunch length. Sensitivity to pulses as short as 200 to 300 femtoseconds has been demonstrated.
  • Keywords
    accelerator RF systems; electron accelerators; electron guns; free electron lasers; linear accelerators; particle beam bunching; particle beam injection; photocathodes; storage rings; 200 to 300 fs; APS injector; APS linac; APS storage ring; FEL; S-band linear accelerator; coherent microwave transition radiation; electron bunch length; electron guns; electron sources; free-electron laser research; laser photocathode gun; Cathodes; Electron guns; Electron sources; Free electron lasers; Laser transitions; Linear accelerators; Linear particle accelerator; Masers; Ring lasers; Storage rings;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
  • ISSN
    1063-3928
  • Print_ISBN
    0-7803-7738-9
  • Type

    conf

  • DOI
    10.1109/PAC.2003.1289231
  • Filename
    1289231