DocumentCode
409087
Title
Observation of coherent microwave transition radiation in the APS linac
Author
Decker, G. ; Sun, X.
Author_Institution
Argonne Nat. Lab., IL, USA
Volume
4
fYear
2003
fDate
12-16 May 2003
Firstpage
2688
Abstract
The APS injector includes a conventional S-band linear accelerator with three separate electron sources. Two electron guns are used as primary and secondary sources for injection into the APS 7-GeV storage ring, while a separate laser photocathode gun is available for free-electron laser (FEL) research. We report here the results of the dependence of 30-GHz coherent microwave transition radiation on electron bunch length. Sensitivity to pulses as short as 200 to 300 femtoseconds has been demonstrated.
Keywords
accelerator RF systems; electron accelerators; electron guns; free electron lasers; linear accelerators; particle beam bunching; particle beam injection; photocathodes; storage rings; 200 to 300 fs; APS injector; APS linac; APS storage ring; FEL; S-band linear accelerator; coherent microwave transition radiation; electron bunch length; electron guns; electron sources; free-electron laser research; laser photocathode gun; Cathodes; Electron guns; Electron sources; Free electron lasers; Laser transitions; Linear accelerators; Linear particle accelerator; Masers; Ring lasers; Storage rings;