DocumentCode :
40915
Title :
Estimation of High-Frequency Parameters of AC Machine From Transmission Line Model
Author :
Younggon Ryu ; Bo-Ryang Park ; Ki Jin Han
Author_Institution :
Sch. of Electr. & Comput. Eng., Ulsan Nat. Inst. of Sci. & Technol., Ulsan, South Korea
Volume :
51
Issue :
3
fYear :
2015
fDate :
Mar-15
Firstpage :
1
Lastpage :
4
Abstract :
This paper proposes a modeling method to estimate the high frequency (HF) characteristics of stator winding in an ac machine. From the frequency response of windings, the proposed method extracts frequency-dependent per-unit-length (PUL) transmission line parameters, which are simplified to a PUL equivalent circuit, including low-frequency and HF components. The newly developed PUL circuit provides a simple distributed-element winding model that captures HF behaviors accurately, and the modeling procedure can be easily adopted for an initial design with simulation data. To verify the proposed method, input impedance from a constructed equivalent circuit of an induction machine was compared with the measurement results. In addition, the concept of effective length, which is involved with antiresonance phenomena, is presented based on the proposed method.
Keywords :
AC machines; equivalent circuits; frequency response; power system parameter estimation; stators; transmission line theory; AC machine; PUL; PUL equivalent circuit; distributed-element winding model; frequency-dependent per-unit-length; high-frequency parameters estimation; stator winding; transmission line model; windings frequency response; AC motors; Equivalent circuits; Integrated circuit modeling; Power transmission lines; Stator windings; Transmission line measurements; Windings; AC motors; electromagnetic compatibility; per-unit-length (PUL) equivalent circuit model; transmission line;
fLanguage :
English
Journal_Title :
Magnetics, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9464
Type :
jour
DOI :
10.1109/TMAG.2014.2355718
Filename :
7093472
Link To Document :
بازگشت