    Improvement of the storage ring UHV system of NSRL

  • Author

    Wang, Y. ; Wei, W. ; Zhao, F.Y. ; Wang, J.P. ; Jing, D.M. ; Fan, L. ; Guan, C.Y. ; Wu, Guanyuan

  • Author_Institution
    Nat. Synchrotron Radiat. Laboratory, Univ. of Sci. & Technol. of China, Hefei, China
  • Volume
    2
  • fYear
    2003
  • fDate
    12-16 May 2003
  • Firstpage
    815
  • Abstract
    NSRL storage-ring has been operated for fourteen years, The typical life time is 600 mins at 200 mA and 800 MeV. The new injection ceramic chamber, bend chamber, undulator and NEG pumps were installed, new vacuum measure and control system was debugged in 2002 summer, as part of NSRL phase II project to enhance the quality, stability and long-term reliability. The average pressure of storage ring is better than 2E-8 Pascal after 48 hour large current direct backout and 48 hour ion pumps operation, this better vacuum can benefit the phase II project´s object, beam lifetime 600 mins at 300 mA and 800 MeV.
  • Keywords
    accelerator control systems; particle beam dynamics; particle beam injection; particle beam stability; storage rings; wigglers; 200 mA; 300 mA; 600 min; 800 MeV; NEG pumps; NSRL phase II project; NSRL storage-ring; beam lifetime; bend chamber; control system; injection ceramic chamber; ion pumps operation; stability; storage ring UHV system; undulator; Control systems; Electrons; Laboratories; Laser excitation; Optical harmonic generation; Stability; Storage rings; Synchrotron radiation; Undulators; Vacuum systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
  • ISSN
    1063-3928
  • Print_ISBN
    0-7803-7738-9
  • Type

    conf

  • DOI
    10.1109/PAC.2003.1289487
  • Filename
    1289487