• DocumentCode
    409179
  • Title

    Magnet-related failure experiences at the SPring-8 storage ring

  • Author

    Tsumaki, K. ; Kumagai, N. ; Matsui, S. ; Ohishi, M. ; Yonehara, H. ; Tateishi, T. ; Torii, Y.

  • Author_Institution
    SPring-8, Hyogo, Japan
  • Volume
    2
  • fYear
    2003
  • fDate
    12-16 May 2003
  • Firstpage
    884
  • Abstract
    High operation rate is required for synchrotron radiation sources for their many users. Keeping high operation rate, we need to maintain the equipments continually and raise the reliability of each component. To raise the reliability, it is important to clarify the cause of failure of equipments. In this paper, we describe the major magnet-related failure experiences of the past six years for the SPring-8 storage ring: failure of flow switch, dissolution of copper in water, and radiation damage of equipments.
  • Keywords
    electron accelerators; particle beam diagnostics; radiation effects; storage rings; synchrotron radiation; SPring-8 storage ring; equipment failure; flow switch; high operation rate; magnet-related failure experiences; radiation damage; synchrotron radiation sources; Coils; Cooling; Copper; Hoses; Magnetic switching; Maintenance; Rubber; Storage rings; Switches; Synchrotron radiation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2003. PAC 2003. Proceedings of the
  • ISSN
    1063-3928
  • Print_ISBN
    0-7803-7738-9
  • Type

    conf

  • DOI
    10.1109/PAC.2003.1289516
  • Filename
    1289516