Abstract :
Seven insertion devices must be provided for the first DIAMOND beamlines on Day 1 of operations. A variety of devices have been selected, including four short period in-vacuum undulators, one 5 m conventional planar undulator, one 5 m helical undulator and a 3.5 T superconducting wiggler. Construction of several of these devices will soon commence. This paper will detail the magnetic solutions that have been adopted and also the mechanical designs, highlighting the key features that have been included.
Keywords :
electron accelerators; superconducting magnets; wigglers; 3.5 T; 5 m; DIAMOND beamlines; DIAMOND insertion devices; conventional planar undulator; helical undulator; magnetic solutions; short period in-vacuum undulators; superconducting wiggler; Intrusion detection; Laboratories; Light sources; Magnetic devices; Magnetic materials; Polarization; Process design; Structural beams; Superconducting magnets; Undulators;