• DocumentCode
    410164
  • Title

    A portable, low-cost, highly integrated, 3D medical ultrasound system

  • Author

    Fuller, Michael I. ; Blalock, Travis N. ; Hossack, John A. ; Walker, William F.

  • Author_Institution
    Biomed. Eng., Virginia Univ., Charlottesville, VA, USA
  • Volume
    1
  • fYear
    2003
  • fDate
    5-8 Oct. 2003
  • Firstpage
    38
  • Abstract
    A design is presented, with prototype component experimental results, of a portable, low-cost 3D ultrasound system that utilizes innovative integrated circuit (IC) topologies and beamforming algorithms to condense the beamforming process into a small custom IC coupled with a generic, commercially available DSP chip. Furthermore, the system includes a low-cost, fully sampled 2D transducer array placed directly adjacent to the receive circuitry allowing precise impedance matching and improved SNR.
  • Keywords
    biomedical ultrasonics; digital signal processing chips; impedance matching; integrated circuit design; ultrasonic transducer arrays; 2D transducer array; 3D medical ultrasound system; DSP chip; IC; beamforming algorithms; beamforming process; digital signal processor; impedance matching; integrated circuit; low cost system; portable system; signal noise ratio; Algorithm design and analysis; Array signal processing; Circuit topology; Coupling circuits; Digital signal processing chips; Impedance matching; Optical coupling; Prototypes; Ultrasonic imaging; Ultrasonic transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics, 2003 IEEE Symposium on
  • Print_ISBN
    0-7803-7922-5
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2003.1293352
  • Filename
    1293352