Data analysis on performance of PV system installed in south and north directions
Author
Yamaguchi, Toshiyulu ; Kawakami, Masanao ; Kitano, Keiichi ; Nakagawa, Shigeyasu ; Tokoro, Tetsuro ; Nakano, Takumi ; Hayama, Kiyoteru ; Ohyama, Hidemori
Author_Institution
Dept. of Electr. Eng., Wakayama Nat. Coll. of Technol., Japan
Volume
3
fYear
2003
fDate
18-18 May 2003
Firstpage
2239
Abstract
The output performance, the solar irradiation and the PV module temperature has been investigated for a PV system installed in south and north direction in a period of 1 year. The average solar radiation per a day in south and north direction was 4.59 kW h/m/sup 2/ and 3.14 kW h/m/sup 2/, respectively. The average temperature of PV module installed in north direction was smaller than that in south direction. We estimated the electric power of 40 kW PV system installed in north direction from the variation of solar radiation and PV module temperature for south and north direction. The ratio of the generated power in the monthly was calculated to be from 96.4% to 32.8%, which average value in a year was 66.4%.
Keywords
photovoltaic power systems; solar cells; 1 yr; 40 kW; data analysis; electric power; photovoltaic module temperature; power generation; solar irradiation; solar radiation;