DocumentCode :
416810
Title :
Unsteady flow measurement using characteristics of closed cylindrical air chamber
Author :
Inaoka, H. ; Shimizu, M. ; Ishida, A.
Author_Institution :
Tokyo Med. & Dental Univ., Japan
Volume :
3
fYear :
2003
fDate :
4-6 Aug. 2003
Firstpage :
3070
Abstract :
This paper deals with a method of unsteady flow measurement. This method utilizes a closed cylindrical air chamber installed in the pipeline. In this method, the volume change of the air chamber is calculated using the characteristics of the chamber. Good agreement was achieved between the measured and the calculated unsteady flow rate, and then the accuracy of this method was discussed.
Keywords :
flow instability; flow measurement; pipe flow; pipelines; closed cylindrical air chamber; pipeline; unsteady flow measurement; unsteady flow rate;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
SICE 2003 Annual Conference
Conference_Location :
Fukui, Japan
Print_ISBN :
0-7803-8352-4
Type :
conf
Filename :
1323875
Link To Document :
بازگشت