DocumentCode
417093
Title
A new design method for transient response control
Author
Kim, Daekwan ; Kim, Hansil ; Choi, Wonho
Author_Institution
Sch. of Electr. Eng., Ulsan Univ., South Korea
Volume
2
fYear
2003
fDate
4-6 Aug. 2003
Firstpage
2255
Abstract
This paper presents that a transient response control is based on certain relations which are related to characteristic polynomial coefficients. It is known to characteristic ratios and characteristic pulsatances by Naslin. We developed an approach to directly control the transient response. Firstly, speed of the response can be controlled by reconstruction form via multipliable characteristic pulsatances. Secondly, overshoot is controlled by reconstruction form via multipliable characteristic ratios. These formulas can be to independently characterize the system overshoot to a step input and the speed of response, respectively. This study is shown to be an efficient control technique to solve the transient response.
Keywords
control system analysis; control system synthesis; frequency response; linear systems; pole assignment; polynomials; stability; step response; transfer functions; transient response; characteristic polynomial coefficients; direct control; linear system; multipliable characteristic pulsatances; multipliable characteristic ratios; overshoot control; reconstruction form; response speed control; step response; transient response control;
fLanguage
English
Publisher
ieee
Conference_Titel
SICE 2003 Annual Conference
Conference_Location
Fukui, Japan
Print_ISBN
0-7803-8352-4
Type
conf
Filename
1324336
Link To Document