Abstract
A transfinite nonlinear resistive network need not have any operating point in the sense that Kichhoff´s current law may be violated at some nodes of infinite degree and Kirchhoff´s voltage law may be violated around some transfinite loops. This is so when standard analysis is used to determine branch voltages and currents. However, by borrowing some techniques of nonstandard analysis, we can show that Kirchhoff´s laws will be satisfied everywhere when branch voltages and currents are determined as hyperreals (i.e., as nonstandard numbers).
Keywords
network topology; nonlinear network analysis; Kirchhoff current law; Kirchhoff voltage law; hyperreal operating points; nonlinear transfinite networks; nonstandard analysis; standard analysis; transfinite loops; transfinite nonlinear resistive network; Extremities; H infinity control; Resistors; Terminology; Voltage;