DocumentCode :
420820
Title :
On-line rotor mixed fault diagnosis way based on spectrum analysis of average instantaneous power in squirrel cage induction motors
Author :
Zhenxing Liu ; Xianglong Zhang ; Yin Xianggen ; Zhang Zhe
Author_Institution :
Wuhan University of Science and Technology
Volume :
2
fYear :
2004
fDate :
15-19 June 2004
Firstpage :
1731
Lastpage :
1735
Abstract :
An approach of on-line condition monitoring and mixed faults diagnosis for the squirrel cage induction motors is introduced in this paper. The proposed approach is based on spectral analysis of the average instantaneous power, which requires no stator or rotor parameters and has ability to separate mixed rotor faults. Theoretical analysis and experimental results demonstrate the effectiveness of the approach.
Keywords :
Condition monitoring; Fault diagnosis; Induction motors; Rotors; Spectral analysis; Stators; diagnosis; fault; monitoring; spectrum analysis; squirrel cage induction motors;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Intelligent Control and Automation, 2004. WCICA 2004. Fifth World Congress on
Conference_Location :
Hangzhou, China
Print_ISBN :
0-7803-8273-0
Type :
conf
DOI :
10.1109/WCICA.2004.1340969
Filename :
1340969
Link To Document :
بازگشت