    Scattering model of whole blood at hemoglobin glycation monitored by refractive index measurement with OCT

  • Author

    Tuchin, Valery V. ; Wang, Ruikang K. ; Galanzha, Ekaterina L. ; Zhestkov, Dmitry M.

  • Author_Institution
    Dept. of Opt., Saratov State Univ., Russia
  • Volume
    2
  • fYear
    2004
  • fDate
    16-21 May 2004
  • Abstract
    Scattering coefficient and anisotropy factor of whole blood with glucose have been calculated using Mie theory modified to account for RBC size distribution and packing, and experimental data on OCT measured refractive index of blood. The increase of scattering coefficient and decrease of anisotropy factor were found at elevation of glucose concentration within physiological range.
  • Keywords
    Mie scattering; biomedical optical imaging; blood; molecular biophysics; optical tomography; physiological models; proteins; refractive index; sugar; Mie theory; OCT; RBC packing; RBC size distribution; anisotropy factor; blood; glucose concentration; hemoglobin glycation; refractive index measurement; scattering coefficient;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Lasers and Electro-Optics, 2004. (CLEO). Conference on
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    1-55752-777-6
  • Type

    conf

  • Filename
    1360791