Results of Tests of Three-Dimensionally Integrated Chips Bonded to Sensors
Author :
Deptuch, Grzegorz W. ; Carini, Gabriella ; Collier, Terence ; Grybos, Pawel ; Kmon, Piotr ; Lipton, Ronald ; Maj, Piotr ; Siddons, David P. ; Szczygiel, Robert ; Yarema, Raymond
Author_Institution :
Electr. Eng. Dept., Fermi Nat. Accel. Lab., Batavia, IL, USA
Volume :
62
Issue :
1
fYear :
2015
fDate :
Feb. 2015
Firstpage :
349
Lastpage :
358
Abstract :
The VIPIC1 readout integrated circuit was designed for X-ray Photon Correlation Spectroscopy experiments that are typically performed using mono-energetic (8 keV) X-rays at a synchrotron radiation facility. The device is a pixel detector with sparsification and parallel readout from the groups, yielding high timing resolution. Recent improvements in bonding alignment of wafers resulted in deliveries of 3D bonded wafers. The stacks, bonded with both the Cu-Cu thermo-compression method and the Cu DBI bonding method, yielded operational devices that have been tested. Chips (with a pixel pitch of 80 μm) were also bonded to silicon pixelated sensors (with a pixel pitch of 100 μm) and the assemblies were exposed to X-ray sources for the first time. The paper focuses on the test results, including the calibrated noise (ENC) and the conversion gain. The noise measured corresponded to 39 e- and 70 e- , respectively for the readout channels that were not connected and connected to the sensor diodes. The conversion gain varied from 43 to 52 μV/e- as a function of the bias current in the front-end block. Essentially all the pixels on a small prototype were operational.
Keywords :
X-ray detection; X-ray photoelectron spectra; image sensors; integrated circuit design; lead bonding; readout electronics; synchrotron radiation; three-dimensional integrated circuits; wafer bonding; 3D bonded wafers; Cu DBI bonding method; Cu-Cu thermo-compression method; ENC; VIPIC1 readout integrated circuit; X-ray photon correlation spectroscopy; X-ray sources; bias current; calibrated noise; conversion gain; electron volt energy 8 keV; front-end block; high timing resolution; mono-energetic X-rays; parallel readout; pixel detector; readout channels; sensor diodes; silicon pixelated sensors; synchrotron radiation facility; three-dimensionally integrated chip testing; wafer bonding alignment; Aluminum; Bonding; Nickel; Noise; Pediatrics; Sensors; Three-dimensional displays; Active pixel sensors; X-ray detectors; bonding processes; mixed analog digital integrated circuits; semiconductor radiation detectors; three-dimensional integrated circuits; through-silicon vias; wafer bonding;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.2014.2378784