Title :
Study of line-commutated thyristor inverter under voltage dips and novel ride-through solution
Author :
Tian, H.Y. ; Sng, E.K.K.
Author_Institution :
Center for Adv. Power Electron., Nanyang Technol. Univ., Singapore
Abstract :
From industrial experience, it is known that three-phase line commutated thyristor inverters encounter commutation failure during voltage dips. Following commutation failure, both upper & lower thyristors belonging to the same leg of the inverter conduct and a surge current results. This paper gives an analysis of this phenomenon in the event of a single-phase dip. A novel and simple solution for turning off the thyristors in the shorted leg is presented. The proposed scheme detects the short circuit and switches off the thyristors to avoid damage due to excessive current build up. When the three-phase source recovers from the dip, the inverter resumes its normal operation. The proposed scheme has quick response and requires no separate voltage source for control circuits. Experimental verification of the thyristor´s turn off mechanism is presented to validate the operation principle.
Keywords :
commutation; failure analysis; invertors; power supply quality; thyristor convertors; commutation failure; control circuits; encounter commutation failure; industrial experience; line-commutated thyristor inverter; single-phase dips; surge current; thyristors turn off mechanism; voltage dips;
Conference_Titel :
Power Electronics and Motion Control Conference, 2004. IPEMC 2004. The 4th International
Conference_Location :
Xi´an
Print_ISBN :
7-5605-1869-9