Abstract :
Intracortical microelectrodes play a prominent role in the operation of neural interfacing systems. They provide an interface for recording neural activities and modulating their behavior through electric stimulation. The performance of such systems is thus directly meliorated by advances in electrode technology. We present a new architecture for intracortical electrodes designed to increase the number of recording/stimulation channels for a given set of shank dimensions. The architecture was implemented on silicon using microfabrication process and fabricated 3-mm-long electrode shanks with six relatively large (110 μm×110 μm) pads in each shank for electrographic signal recording to detect important precursors with potential clinical relevance and electrical stimulation to correct neural behavior with low-power dissipation in an implantable device. Moreover, an electrode mechanical design was developed to increase its stiffness and reduce shank deflection to improve spatial accuracy during an electrode implantation. Furthermore, the pads were post-processed using pulsated low current electroplating and reduced their impedances by ~ 30 times compared to the traditionally fabricated pads. The paper also presents microfabrication process, electrodes characterization, comparison to the commercial equivalents, and in vitro and in vivo validations.
Keywords :
bioelectric phenomena; biomedical electrodes; electroplating; elemental semiconductors; microelectrodes; microfabrication; neurophysiology; patient monitoring; prosthetics; silicon; Si; electrical stimulation; electrode implantation; electrode mechanical design; electrode shanks; electrographic signal recording; fine-resolution neuromonitoring; high-density intracortical microelectrode arrays; impedance; implantable device; in vitro validation; in vivo validation; low-power dissipation; microfabrication; multiple metallization layers; neural activity; neural behavior; neural interfacing systems; neurostimulation; pulsated low current electroplating; recording channels; shank deflection; shank dimension; size 3 mm; stimulation channels; Electrodes; Force; Impedance; Layout; Manganese; Silicon; Stress; Functional electric stimulation (FES); intracortical electrodes; microelectrode arrays; neural interfacing; Action Potentials; Animals; Cells, Cultured; Computer-Aided Design; Electric Impedance; Electric Stimulation Therapy; Electrodes, Implanted; Equipment Design; Equipment Failure Analysis; Hippocampus; Humans; Metals; Microarray Analysis; Microelectrodes; Rats; Rats, Wistar;
fLanguage :
English
Journal_Title :
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
1534-4320
Type :
jour
DOI :
10.1109/TNSRE.2013.2279403
Filename :
6623209
Link To Document :
بازگشت