DocumentCode :
426280
Title :
A high-precision calibration method for distorted camera
Author :
Chuan, Zhou ; Long, Tan Da ; Feng, Zhu
Author_Institution :
Shenyang Inst. of Autom., Chinese Acad. of Sci., China
Volume :
3
fYear :
2004
fDate :
28 Sept.-2 Oct. 2004
Firstpage :
2618
Abstract :
This paper proposes a calibration strategy for distorted camera with high precision. It makes use of planar homography constraint to estimate the intrinsic and extrinsic parameters. On the basis of this initial guess, an optimization scheme is used to minimize a new cost function, which is based on a perspective 3-point (P3P) algorithm. All the calibration parameters are globally optimized simultaneously with genetic algorithm (GA). Simulation and real image experiment result show this technique have much higher precision than traditional methods.
Keywords :
calibration; cameras; genetic algorithms; cost function; distorted camera; genetic algorithm; high-precision calibration method; optimization scheme; perspective 3-point algorithm; planar homography constraint; Calibration; Cameras; Convergence; Cost function; Laboratories; Optimization methods; Pollution measurement; Robot kinematics; Robot vision systems; Robotics and automation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Intelligent Robots and Systems, 2004. (IROS 2004). Proceedings. 2004 IEEE/RSJ International Conference on
Print_ISBN :
0-7803-8463-6
Type :
conf
DOI :
10.1109/IROS.2004.1389803
Filename :
1389803
Link To Document :
بازگشت