Abstract
The fast generation of digitally reconstructed radiographs is a prerequisite for intensity-based registration approaches. For our approach, extensive pre-calculations are necessary that are saved in what we call a direction dependent projection field. The projection field approach reduces the complexity of the DRR calculation from O(n3) to O(n2). This work develops the theoretical background and gives first examples of the application of projection fields for the 2D/3D registration of X-rays to CT data.
Keywords
computerised tomography; diagnostic radiography; image reconstruction; image registration; medical image processing; computerised tomography; direction dependent projection fields; fast digitally reconstructed radiographs generation; medical 2D/3D X-ray registration; Biomedical applications of radiation; Biomedical imaging; Casting; Computed tomography; Interpolation; Ionizing radiation; Iterative algorithms; Medical treatment; Portals; X-ray imaging; Projection fields; radiotherapy; registration;