• DocumentCode
    429336
  • Title

    EEG source localization using differential evolution method

  • Author

    Li, Ying ; Li, Haitao ; He, Renjie ; Rao, Liyun ; Wu, Qing ; Xu, Guizhi ; Shen, Xueqin ; Yan, Weili

  • Author_Institution
    Hebei Univ. of Technol., Tianjin, China
  • Volume
    1
  • fYear
    2004
  • fDate
    1-5 Sept. 2004
  • Firstpage
    1903
  • Lastpage
    1906
  • Abstract
    Differential evolution (DE) method is used in This work to solve the EEG source localization problem based on equal current dipole model. The single dipole sources with four-shell concentric sphere model are reconstructed. Our simulations demonstrate that DE algorithm is robust in obtaining high quality reconstruction for EEG problems with single current dipole sources.
  • Keywords
    electroencephalography; inverse problems; medical signal processing; signal reconstruction; EEG source localization; differential evolution method; equal current dipole model; four-shell concentric sphere model; single dipole source reconstruction; Biomedical imaging; Brain modeling; Electric variables measurement; Electrodes; Electroencephalography; Head; Image reconstruction; Inverse problems; Optimization methods; Scalp; Differential Evolution; EEG source localization; equal current dipole model; inverse problem;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2004. IEMBS '04. 26th Annual International Conference of the IEEE
  • Conference_Location
    San Francisco, CA
  • Print_ISBN
    0-7803-8439-3
  • Type

    conf

  • DOI
    10.1109/IEMBS.2004.1403564
  • Filename
    1403564