DocumentCode :
432077
Title :
Feasibility of noninvasive transesophageal cardiac thermal ablation using an ultrasound phased array
Author :
Yin, Xiangtao ; Epstein, Laurence M. ; Hynynen, Kullervo
Author_Institution :
Dept. of Radiol., Brigham & Women´´s Hosp., Boston, MA, USA
Volume :
1
fYear :
2004
fDate :
23-27 Aug. 2004
Firstpage :
126
Abstract :
Current, minimally invasive, treatments for cardiac arrhythmia use a transvenous radio-frequency (RF) catheter to ablate the malfunctioning cardiac muscle regions. The paper proposes a noninvasive transesophageal cardiac thermal ablation using focused ultrasound. A planar phased array (1 MHz, 60×10 mm2, 0.525 mm element center-to-center distance, 2280 elements) was put in the esophagus. Using electronic beam steering, a matrix of 5×3×5 foci in the cardiac muscle was defined in three planes parallel to the transducer surface at short, medium and long (20, 40 and 60 mm) radial ranges and different steering angles. The transmitted ultrasound pressure distribution in a volume of 20×20×20 mm3 centered at each focus was calculated using a multilayer acoustic wave transmission model. The thermal lesions due to the acoustic energy absorption in cardiac muscle were simulated using the bioheat transfer equation. For short, medium and long (1-, 10- and 20-second) sonications, the acoustic powers needed to achieve 60°C and 70°C peak temperatures in the cardiac muscle were 89-725, 25-125, 20-86 W and 128-1040, 36-179, 28-123 W, respectively. The simulated tissue lesion (thermal dose >240 min at 43°C) lengths at these foci were 2-10, 5-12, 6-14 mm and 3-13, 7-15, 9-17 mm, respectively. The lesion widths were 2-8, 3-10, 4-11 mm and 3-11, 4-12, 5-13 mm, respectively. The simulations show that noninvasive transesophageal cardiac ablation with a planar phased ultrasound array is feasible.
Keywords :
beam steering; biomedical ultrasonics; cardiology; heat transfer; hyperthermia; muscle; patient treatment; ultrasonic absorption; ultrasonic effects; ultrasonic transducer arrays; 1 MHz; 1 to 20 sec; 10 to 60 mm; 2 to 17 mm; 20 to 1044 W; 20 to 60 mm; 43 C; 60 C; 70 C; acoustic energy absorption; acoustic power; bioheat transfer equation; cardiac arrhythmia; cardiac muscle; electronic beam steering; focused ultrasound; multilayer acoustic wave transmission model; noninvasive transesophageal cardiac thermal ablation; planar phased array; thermal lesions; tissue lesion; ultrasound phased array; Beam steering; Catheters; Esophagus; Lesions; Minimally invasive surgery; Muscles; Phased arrays; Radio frequency; Transmission line matrix methods; Ultrasonic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2004 IEEE
ISSN :
1051-0117
Print_ISBN :
0-7803-8412-1
Type :
conf
DOI :
10.1109/ULTSYM.2004.1417684
Filename :
1417684
Link To Document :