• DocumentCode
    432096
  • Title

    Synthetic aperture angular scatter imaging: system refinement

  • Author

    Guenther, D.A. ; Ranganathan, K. ; McAllister, M.J. ; Walker, W.F. ; Rigby, K.W.

  • Author_Institution
    Dept. of Biomed. Eng., Virginia Univ., Charlottesville, VA, USA
  • Volume
    1
  • fYear
    2004
  • fDate
    23-27 Aug. 2004
  • Firstpage
    243
  • Abstract
    Angular scatter imaging has been proposed as a new source of image contrast in medical ultrasound and as a parameter for tissue characterization. We describe a new method that combines the translating apertures algorithm (TAA) with synthetic aperture methods to coherently obtain angular scatter information with high resolution in both space and scattering angle. This method, which we term synthetic aperture angular scatter (SAAS) imaging effectively applies the TAA to single array elements and then focuses the data synthetically to form high resolution images at precisely defined scattering angles. In this paper, we present experimental results implementing SAAS to form angular scatter images of a 5-wire depth of field phantom, a tissue mimicking 3-wire phantom, and in vivo human thyroid. We discuss the degree of uniformity necessary in element response for successful SAAS imaging. These experiments show new image information previously unavailable in conventional B-mode images and suggest that angular scatter imaging may have applications in the breast, thyroid, and peripheral vasculature.
  • Keywords
    biomedical ultrasonics; image resolution; phantoms; ultrasonic focusing; ultrasonic scattering; SAAS imaging; breast tissue imaging; data synthetic focusing; image contrast source; in vivo human thyroid imaging; medical ultrasound; peripheral vasculature imaging; scatter information resolution; scattering angle; synthetic aperture angular scatter imaging; tissue characterization; tissue mimicking phantom; translating apertures algorithm; Biomedical imaging; Breast; Focusing; High-resolution imaging; Humans; Image resolution; Imaging phantoms; In vivo; Scattering parameters; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2004 IEEE
  • ISSN
    1051-0117
  • Print_ISBN
    0-7803-8412-1
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2004.1417712
  • Filename
    1417712