DocumentCode
432292
Title
Algorithms of three-dimensional beam forming for synthetic aperture imaging system using pulses coded with Walsh functions [ultrasonic imaging]
Author
Satoh, Keiichi ; Miura, Masashi ; Tamura, Yasutaka ; Yanagida, Hirotaka ; Yamasaki, Takashi ; Ishihara, Chiaki ; Okada, Nagaya
Author_Institution
Dept. of Informatics, Yamagata Univ., Japan
Volume
2
fYear
2004
fDate
23-27 Aug. 2004
Firstpage
1405
Abstract
An imaging system using coded transmission with Walsh functions has been developed by the authors for high-frame-rate 3D observation. This system enables us to observe a sequence of 3D images of moving objects for each transmission. However, the speed of computation is one of the most important issues in practical applications. In this paper, we describe two algorithms of 3D beam forming for a high-frame-rate synthetic aperture imaging system using transmitting pulses coded with Walsh functions.
Keywords
Walsh functions; image reconstruction; image sequences; modulation coding; ultrasonic imaging; 3D beam forming; 3D image sequence; Walsh function coded pulses; Walsh function modulation; coded transmission imaging system; high-frame-rate 3D observation; image reconstruction; moving object image sequence; synthetic aperture imaging; ultrasonic imaging; Clocks; Equations; Focusing; Frequency; Image reconstruction; Informatics; Optical modulation; Pulse modulation; Transmitters; Ultrasonic imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium, 2004 IEEE
ISSN
1051-0117
Print_ISBN
0-7803-8412-1
Type
conf
DOI
10.1109/ULTSYM.2004.1418062
Filename
1418062
Link To Document