DocumentCode :
432368
Title :
Optimal conditions efficiency for pulse increasing the breakdown strength of vacuum insulation
Author :
Emelyanov, A.A. ; Emelyanova, E.A. ; Safonova, T.N. ; Serikov, I.O.
Author_Institution :
IEEE Conference Publishing, 29, Naugorskoe shosse, OryolSTU, Oryol, 302020 Russia
Volume :
1
fYear :
2004
fDate :
Sept. 27 2004-Oct. 1 2004
Firstpage :
9
Lastpage :
11
Abstract :
High-voltage conditioning efficiency of vacuum gap electrodes at the electric field macrointensity, 1.5.107⩽E01.310V/m , by pulses with duration equal to the breakdown delay time is estimated. It´s shown that pulse regimes efficiency for increasing the vacuum insulation breakdown strength rises with duration decrease at appropriate intensity increase on cathode and can essential exceed dc conditioning efficiency. Limiting results correspond to the conditioning with the subnanosecond pulses at the macrointensity, E0˜1010V/m, created in micron gaps.
Keywords :
Cathodes; Copper; Delay effects; Delay estimation; Electric breakdown; Electrodes; Insulation; Publishing; Pulse amplifiers; Vacuum breakdown;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Discharges and Electrical Insulation in Vacuum, 2004. Proceedings. ISDEIV. XXIst International Symposium on
Conference_Location :
Yalta, Crimea
ISSN :
1093-2941
Print_ISBN :
0-7803-8461-X
Type :
conf
DOI :
10.1109/DEIV.2004.1418586
Filename :
1418586
Link To Document :