• DocumentCode
    434096
  • Title

    Full voltage effect at the pulse increasing of vacuum insulation electric strength

  • Author

    Emelyanov, A.A. ; Emelyanova, E.A. ; Kubyshkina, M.V.

  • fYear
    2004
  • fDate
    21-24 Sept. 2004
  • Firstpage
    217
  • Lastpage
    217
  • Abstract
    Full voltage effect influence on electrodes pulse processing efficiency in vacuum is estimated. At simultaneous reduction of pulse duration and gap length, the processing is accompanied with reduction of field amplification factor on cathode surface microinhomogeneities more than on two orders of magnitude in comparison with long influence voltage and centimeter gaps at the expense of both the pulses capacity increase and the full complete voltage effect. In comparison with long influence voltage at the same gap length, the pulse processing provides additional increase of cathode surface quality at the expense of pulses capacity increase, which reaches 40 multiple in the micron gaps at the subnanosecond duration pulses.
  • Keywords
    Cathodes; Coatings; Dielectrics and electrical insulation; Intermetallic; Isotopes; Magnetic separation; Mesh generation; Pulse amplifiers; Voltage; Wheels;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Instrument Engineering Proceedings, 2004. APEIE 2004. 2004 7th International Conference on Actual Problems of
  • Conference_Location
    Novosibirsk, Russia
  • Print_ISBN
    0-7803-8476-8
  • Type

    conf

  • Filename
    1427235