Title :
Radiated emission measurement of small EUT by using a reverberation chamber
Author :
Harima, Katsushige
Author_Institution :
Commun. Res. Lab., Kanagawa, Japan
Abstract :
In radiated emission testing, based on the measurement of the total radiated power by using reverberation chambers and TEM devices, the e-field strength is correlated with the radiated power by assuming the maximum directivity of the equipment under test (EUT). For small EUT, the directivity of a short dipole is often used. This work describes how the emission e-field strength of small EUT was measured by using the substitution method in a reverberation chamber. These results were compared with those obtained using a GTEM-cell and an anechoic chamber. The experimental results showed an error caused by the assumption of the directivity in the correlated e-field strength; however, the reverberation chamber effectively measured the total radiated power. The total radiated power of the EUT with the directivity of a dipole measured by using a GTEM-cell was shifted 6 dB lower than that measured with a reverberation chamber.
Keywords :
TEM cells; anechoic chambers (electromagnetic); electric field measurement; electronic equipment testing; reverberation chambers; GTEM-cell; TEM devices; anechoic chamber; e-field strength; equipment under test; radiated emission measurement; radiated emission testing; reverberation chamber; short dipole; small EUT; substitution method; total radiated power; Anechoic chambers; Antenna measurements; Open area test sites; Power measurement; Receiving antennas; Reverberation chamber; Spectral analysis; Testing; Transmitting antennas; Wavelength measurement;
Conference_Titel :
Electromagnetic Compatibility, 2003. EMC '03. 2003 IEEE International Symposium on
Print_ISBN :
0-7803-7779-6
DOI :
10.1109/ICSMC2.2003.1428294