Title :
Reliability of Bi-2223/AgAu Current Leads for Cryocooled Superconducting Magnet
Author :
Tsurudome, T. ; Yoshida, J. ; Ookubo, H. ; Mikami, Yuya ; Mitsubori, H. ; Kato, Toshihiko ; Sakuraba, J. ; Watazawa, K.
Author_Institution :
Technol. Res. Center, Sumitomo Heavy Ind., Ltd., Yokosuka, Japan
Abstract :
A current lead for a cryocooled superconducting magnet (CSM) was designed and fabricated using a high-temperature superconductor (HTS) tape, which could easily facilitate modification of the transport current capacity. The current lead was constructed of two terminal blocks, a support tube, and five Bi2223/AgAu HTS tapes. The Bi2223/AgAu HTS tapes with a critical current of 100 A at 77 K in self-fields were used for the current leads. The critical current value of the current lead was 390 A at 77 K in self-fields. The initial critical current at 77 K was maintained after four thermal cycles. The transport current of 170 A was continuously applied at 75 K, 0.27 T by conduction cooling. The voltage between two terminal blocks was 0.28 mV, even after 930 cycles of electromagnetic force (Lorentz force). The heat leakage through the current lead was 0.21 W from 55 K stage to 4.5 K stage. The experimental results showed that the current lead for CSM had sufficient strength against thermal stress and Lorentz force. The current lead has been operated in a CSM to demonstrate a stable excitation and reliability after thermal cycles from room temperature to 4 K. During the excitation and thermal cycle test, overall voltage of the current lead was maintained at an operational condition of 155 A, 55 K, and 0.26 T.
Keywords :
bismuth compounds; calcium compounds; cooling; critical currents; gold alloys; high-temperature superconductors; silver alloys; strontium compounds; superconducting magnets; superconducting tapes; thermal stresses; Bi2223-AgAu HTS tapes; Bi2Sr2Ca2Cu3O8-AgAu; Lorentz force; conduction cooling; cryocooled superconducting magnet; current 100 A; current 155 A; current 170 A; current 390 A; current lead reliability; electromagnetic force cycles; heat leakage; high-temperature superconductor tape; initial critical current; operational condition; overall voltage; self-fields; stable excitation; support tube; temperature 4 K to 298 K; terminal blocks; thermal cycle test; thermal stress; transport current capacity modification; voltage 0.28 mV; Critical current; Current measurement; Heating; High temperature superconductors; Lorentz covariance; Superconducting magnets; Temperature measurement; Critical current; current lead; high-temperature superconductor; superconducting magnet;
Journal_Title :
Applied Superconductivity, IEEE Transactions on
DOI :
10.1109/TASC.2013.2245282