Abstract :
We recently demonstrated the value of reconstructing SPECT data with fully 3D Monte Carlo reconstruction (F3DMC), in terms of spatial resolution and quantification. This was shown on a small cubic phantom (64 projections 10×10) in some idealistic configurations. The goals of the present study were to assess the effect of noise and modeling errors on the reliability of F3DMC, to propose and evaluate strategies for reducing the noise in the projector, and to demonstrate the feasibility of F3DMC for a dataset with realistic dimensions. A small cubic phantom and a realistic Jaszczak phantom dataset were considered. Projections and projectors for both phantoms were calculated using the Monte Carlo simulation code GATE. Projectors with different statistics were considered and two methods for reducing noise in the projector were investigated: one based on principal component analysis (PCA) and the other consisting in setting small probability values to zero. Energy and spatial shifts in projection sampling with respect to projector sampling were also introduced to test F3DMC in realistic conditions. Experiments with the cubic phantom showed the importance of using simulations with high statistics for calculating the projector, and the value of filtering the projector using a PCA approach. F3DMC was shown to be robust with respect to energy shift and small spatial sampling offset between the projector and the projections. Images of the Jaszczak phantom were successfully reconstructed and also showed promising results in terms of spatial resolution recovery and quantitative accuracy in small structures. It is concluded that the promising results of F3DMC hold on realistic data sets.
Keywords :
Monte Carlo methods; image reconstruction; image resolution; medical image processing; noise; phantoms; principal component analysis; single photon emission computed tomography; F3DMC reconstruction; GATE code; PCA approach; SPECT; cubic phantom; energy shifts; fully 3D Monte Carlo reconstruction; modeling errors; noise reduction; principal component analysis; probability values; projection sampling; projector sampling; realistic Jaszczak phantom dataset; single photon emission computed tomography; spatial resolution; spatial shifts; Image reconstruction; Imaging phantoms; Monte Carlo methods; Noise reduction; Principal component analysis; Probability; Sampling methods; Spatial resolution; Statistical analysis; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Type :
conf
DOI :
10.1109/NSSMIC.2004.1462770
Filename :
1462770
Link To Document :
بازگشت