DocumentCode :
438142
Title :
Application of various iterative reconstruction for quantitative 3D dynamic brain PET studies
Author :
Boellaard, Ronald ; Lubberink, Mark ; De Jong, Hugo ; Kropholler, Marc ; Lammertsma, Adriaan A.
Author_Institution :
Dept. o Nucl. Med. & PET Res., VU Univ. Med. Center, Amsterdam, Netherlands
Volume :
4
fYear :
2004
fDate :
16-22 Oct. 2004
Firstpage :
2553
Abstract :
Iterative image reconstruction algorithms may suffer from bias in case of poor statistics. The purpose of this study is: (1) to implement various existing and new iterative methods and (2) to evaluate the applicability of these methods for quantitative 3D brain PET studies. Various OSEM and weighted least squares (WLS) algorithms were implemented. WLS and WLS with OSEM start image (OS-EM-WLS) were implemented with and w/o nonnegativity constraints. Accuracy and precision were assessed using phantom and simulations studies. Clinical evaluation was performed for 3 tracers using 9 dynamic brain PET studies including arterial sampling. ROI analysis was performed to evaluate contrast, noise and bias. Simulations were used to generate variance images at various noise levels. Dynamic human brain scans were analysed using parametric Logan plot analysis. Phantom data showed that all methods with nonnegativity constraint showed bias up to a factor 4 in low activity areas. Algorithms that allowed negative values within sinogram and image space provided smallest bias. Simulations showed that WLS w/o constraint, but with an OSEM start image, provided lowest variance amongst all tested reconstruction methods. OS-EM-WLS was more accurate and showed lower variance than other methods tested. Finally, parametric Logan analysis showed that OS-EM-WLS agreed most with FBP. OS-EM-WLS provided most accurate results and is therefore a promising candidate for reconstruction of 3D brain PET studies.
Keywords :
brain; image reconstruction; iterative methods; least squares approximations; medical image processing; phantoms; positron emission tomography; OS-EM-WLS algorithms; OSEM start image; ROI analysis; arterial sampling; clinical evaluation; image contrast; image space; iterative image reconstruction algorithms; low activity areas; noise levels; nonnegativity constraints; parametric Logan plot analysis; phantom; quantitative 3D dynamic brain PET studies; sinogram; tracers; variance images; weighted least squares algorithms; Brain modeling; Image reconstruction; Imaging phantoms; Iterative algorithms; Iterative methods; Least squares methods; Performance evaluation; Positron emission tomography; Statistics; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN :
1082-3654
Print_ISBN :
0-7803-8700-7
Type :
conf
DOI :
10.1109/NSSMIC.2004.1462774
Filename :
1462774
Link To Document :
بازگشت