Title
Modified dead time correction for prompt gamma radiation emitting PET isotopes
Author
Lubberink, Mark ; Schneider, Harald ; Lundqvist, Hans
Author_Institution
Dept. of Nucl. Medicine, VU Univ. Med. Centre, Amsterdam, Netherlands
Volume
5
fYear
2004
fDate
16-22 Oct. 2004
Firstpage
3138
Abstract
Several long-lived positron emitters, such as 76Br(t12/=16.2 h, 55% β+) and 124I(t12/=4.2 d, 23% β+, emit photons simultaneously with positrons. Coincidence detection of these photons with each other or with annihilation photons leads to essentially true coincidences that can not be distinguished from coincidences involving two annihilation photons. These photons also lead to higher singles count rates and thus to a higher dead time. Furthermore, photons that are rejected by the energy discriminator, the number of which is considerably increased for prompt gamma emitting nuclides, are not counted as singles but do contribute to dead time and lead to inaccuracy of the standard dead time correction. The aim of the present study was to assess the effect of additional gamma radiation on dead time correction accuracy and to improve the existing dead time correction for prompt gamma emitting nuclides. Singles life time as a function of singles rate is lower for 76Br than for 18F, whereas coincidence life times are similar. Total dead time for 76Br is considerably increased compared to 11C for similar singles count rates. Multiplication of the measured 76Br singles rate with a fixed factor of 1.3 leads to a similar dead time as a function of singles rate as for 11C and in an accurate prediction of the total dead time by the standard dead time correction. Multiplication factors for different energy windows correlate well with the relative number of rejected photons.
Keywords
coincidence techniques; gamma-ray detection; positron emission tomography; 124I; 76Br; PET isotopes; annihilation photons; coincidence detection; coincidence life times; energy discriminator; long-lived positron emitters; modified dead time correction; multiplication factors; prompt gamma radiation; singles count rates; standard dead time correction; Biomedical imaging; Biomedical measurements; Gamma rays; Imaging phantoms; Isotopes; Measurement standards; Medical treatment; Nuclear medicine; Positron emission tomography; Time measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2004 IEEE
ISSN
1082-3654
Print_ISBN
0-7803-8700-7
Electronic_ISBN
1082-3654
Type
conf
DOI
10.1109/NSSMIC.2004.1466346
Filename
1466346
Link To Document