Title :
An event driven read-out system for a novel PET scanner with Compton enhanced 3D gamma reconstruction
Author :
Dragone, A. ; Corsi, F. ; Marzocca, C. ; Losito, P. ; Pasqua, D. ; Nappi, E. ; De Leo, R. ; Séguinot, J. ; Braem, A. ; Chesi, E. ; Joram, C. ; Weilhammer, P. ; Garibaldi, F. ; Zaidi, H.
Author_Institution :
Electr. & Electron. Dept., Politecnico di Bari, Italy
Abstract :
The design of a data acquisition system (DAQ) for a novel positron emission tomography scanner is reported. The PET system, based on long axially oriented scintillation crystals, read out by hybrid photon detectors (HPD), allows 3D parallax-error free Compton enhanced gamma reconstruction. The DAQ system is composed of several read-out cards, each one associated with a module of the PET scanner, and of a main card that controls the whole system. Using fast triggering signals from the silicon sensor back-planes, the main card performs the coincidence analysis, and, in case of coincidence, it enables the read-out of the two modules involved. The other modules are left free to perform new acquisitions. This concept based on several independent, event driven and parallel read-out chains, drastically reduce the acquisition dead time. Each enabled readout card digitizes, encodes and stores data from the respective module. Data are stored in a local FIFO and then are transferred through a network into a single computer. The system is designed according to the specifications of IDEAS VaTaGP5 chip. Each read-out card is able to accommodate all the chip read-out modes and the test procedures and can be used as a standalone read-out system that allows reading out up to 16 daisy chained chips per channel. We describe a simplified DAQ system, designed for a two module demonstrator set-up, developed to study and optimize the essential design parameters.
Keywords :
Compton effect; data acquisition; gamma-ray detection; image reconstruction; image scanners; positron emission tomography; readout electronics; solid scintillation detectors; 3D parallax-error free Compton enhanced gamma reconstruction; DAQ system; IDEAS VaTaGP5 chip; PET scanner; chip read-out modes; coincidence analysis; daisy chained chips; data acquisition system; event driven read-out system; fast triggering signals; hybrid photon detectors; local FIFO; long axially oriented scintillation crystals; positron emission tomography scanner; silicon sensor back-planes; single computer; standalone read-out system; Control systems; Data acquisition; Gamma ray detection; Gamma ray detectors; Optoelectronic and photonic sensors; Photonic crystals; Positron emission tomography; Signal analysis; Silicon; Solid scintillation detectors;
Conference_Titel :
Nuclear Science Symposium Conference Record, 2004 IEEE
Print_ISBN :
0-7803-8700-7
Electronic_ISBN :
1082-3654
DOI :
10.1109/NSSMIC.2004.1466350