Title :
High power millimeter wave magnicon amplifier
Author :
Nezhevenko, O.A. ; Yakovlev, V.P. ; LaPointe, M.A. ; Kozyrev, E.V. ; Shchelkunov, S.V. ; Hirshfield, J.L.
Author_Institution :
Omega-P, Inc., New Haven, CT, USA
Abstract :
A high efficiency, high power magnicon at 34.272 GHz has been designed and built as a microwave source to develop RF technology for a future multi-TeV electron-positron linear collider. To develop this technology, this new RF source is being perfected for necessary tests of accelerating structures, RF pulse compressors, RF components, and to determine limits of breakdown and metal fatigue. To date the magnicon has produced a peak output power of 17 MW with a gain of 47 dB at a repetition rate of up to 5 Hz.
Keywords :
linear colliders; millimetre wave amplifiers; 17 MW; 34.272 GHz; 47 dB; RF components; RF pulse compressors; RF technology; accelerating structures; breakdown limits; high power magnicon; metal fatigue limits; microwave sources; millimeter wave magnicon amplifier; multiTeV electron positron linear collider; Compressors; High power amplifiers; Life estimation; Microwave technology; Millimeter wave technology; Pulse amplifiers; Pulse compression methods; Radio frequency; Radiofrequency amplifiers; Testing;
Conference_Titel :
Infrared and Millimeter Waves and 13th International Conference on Terahertz Electronics, 2005. IRMMW-THz 2005. The Joint 30th International Conference on
Print_ISBN :
0-7803-9348-1
DOI :
10.1109/ICIMW.2005.1572424