Abstract :
We report error-free transmission at 10 Gbit/s over a 110 km, amplified PON using XFP and 300-pin MSA transceivers, super FEC and EDC. Bidirectional operation is implemented over a single fibre in the access network.
Keywords :
forward error correction; optical communication equipment; optical fibre subscriber loops; transceivers; 10 Gbit/s; 1024-way split; 110 km; EDC; FEC; MSA transceivers; PON system; XFP; access network; amplified PON; bidirectional operation; bidirectional transmission; commercial transceiver modules; error-free transmission; single fiber implementation;