DocumentCode :
45017
Title :
Application of Wavelet Transform to Obtain the Frequency Response of a Transformer From Transient Signals—Part II: Practical Assessment and Validation
Author :
Gomez-Luna, E. ; Aponte Mayor, G. ; Pleite Guerra, Jorge
Author_Institution :
Univ. del Valle, Cali, Colombia
Volume :
29
Issue :
5
fYear :
2014
fDate :
Oct. 2014
Firstpage :
2231
Lastpage :
2238
Abstract :
This paper presents a practical assessment and validation for the new proposed approach based on the continuous wavelet transform (CWT) to obtain the frequency response from online transient signals for an actual transformer. Apart from the mathematical procedure, an electronic system was also designed and implemented in order to inject superimposed controlled pulses to the power system (50/60 Hz) wave. The results show improved performance of the wavelet transform compared to the Fourier transform, for transient signal analysis to be applied on a nonintrusive transformer monitoring approach. Particularly, this new approach enables overcoming some problems related to the signal filtering and the signal processing in an online frequency-response analysis transformer diagnosis. This paper is presented in three parts. Part I showed the main theoretical basis of this approach. The current Part II shows a practical assessment based on tests performed in a three-phase transformer of 1150/345 V-5 kVA and in a single-phase transformer of 13200/240 V-15 kVA. Part III shows the performance of this new approach on transformers being diagnosed under real conditions.
Keywords :
filtering theory; frequency response; power system transients; power transformers; wavelet transforms; CWT; apparent power 15 kVA; apparent power 5 kVA; continuous wavelet transform; electronic system; nonintrusive transformer monitoring approach; online frequency-response analysis; online transient signals; power system wave; signal filtering; signal processing; single-phase transformer; three-phase transformer diagnosis; transient signal analysis; voltage 1150 V to 345 V; voltage 13200 V to 240 V; Continuous wavelet transforms; Frequency measurement; Multiresolution analysis; Transient analysis; Windings; Continuous wavelet transform (CWT); frequency response; online monitoring; power system transients; transformers;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/TPWRD.2013.2295377
Filename :
6698401
Link To Document :