DocumentCode :
451446
Title :
High resolution calorimetry with PWO-II
Author :
Novotny, Rainer W. ; Döring, Werner M. ; Hjelm, Frida ; Melnychuk, Diba ; Makonyi, Karoly ; Reiter, Andreas ; Salz, Christof ; Steinacher, Michael ; Thiel, Michaela ; Zwieglinski, Bogdan
Author_Institution :
2nd Phys. Inst., Giessen Univ., Germany
Volume :
1
fYear :
2005
fDate :
23-29 Oct. 2005
Firstpage :
244
Lastpage :
248
Abstract :
The light output of PbWO4 crystals, produced at BTCP, has been significantly enhanced by an improved manufacturing technology. First large size crystals of 150 and 200 mm length have been tested assembled in 3×3 arrays using tagged photons between 64 MeV and 520 MeV energy. The scintillation light has been detected either with commercial photomultiplier tubes or new developed large area silicon avalanche photo diodes of 10×10 mm2 active area. Excellent energy resolutions have been obtained in both cases. For the first time, a timing resolution well below 1 ns has been achieved with diode readout.
Keywords :
avalanche photodiodes; calorimeters; particle calorimetry; photomultipliers; silicon radiation detectors; solid scintillation detectors; PWO-II; PbWO4 crystal light output; diode readout; energy resolutions; high resolution calorimetry; large area silicon avalanche photodiodes; photomultiplier tubes; scintillation light; tagged photons; timing resolution; Assembly; Calorimetry; Diodes; Energy resolution; Manufacturing; Photomultipliers; Photonic crystals; Silicon; Solid scintillation detectors; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2005 IEEE
ISSN :
1095-7863
Print_ISBN :
0-7803-9221-3
Type :
conf
DOI :
10.1109/NSSMIC.2005.1596246
Filename :
1596246