DocumentCode
45661
Title
Magnetron Injection Gun for a Short Pulse, 0.67 THz Gyrotron for Remote Detection of Radioactive Materials
Author
Singh, Upendra ; Kumar, Narendra ; Sinha, Arun Kumar
Author_Institution
Gyrotron Lab., Central Electron. Eng. Res. Inst., Pilani, India
Volume
4
Issue
4
fYear
2014
fDate
Jul-14
Firstpage
509
Lastpage
514
Abstract
In this paper, the design of electron gun for a 0.67 THz gyrotron is presented. The in-house code MIGSYN is used to estimate the initial gun parameters. The electron trajectory tracing 2.5-dimensional (2.5-D) code EGUN is used to optimize the electron gun design. The parametric analysis and misalignment study is also carried out to provide the flexibility in the actual fabrication of the device.
Keywords
design engineering; electron guns; gyrotrons; magnetrons; optimisation; radioactive tracers; terahertz materials; terahertz wave generation; 2.5D code; EGUN; MIGSYN; electron gun design optimisation; electron trajectory tracing; frequency 0.67 THz; gun parameter estimation; gyrotron; magnetron injection gun; parametric analysis; remote radioactive materials detection; Anodes; Cathodes; Electron beams; Fabrication; Gyrotrons; Radioactive materials; Trajectory; Fast-wave devices; THz gyrotron; magnetron injection gun;
fLanguage
English
Journal_Title
Terahertz Science and Technology, IEEE Transactions on
Publisher
ieee
ISSN
2156-342X
Type
jour
DOI
10.1109/TTHZ.2014.2327374