    200 MeV Proton Radiography Studies With a Hand Phantom Using a Prototype Proton CT Scanner

  • Author

    Plautz, Tia ; Bashkirov, V. ; Feng, V. ; Hurley, F. ; Johnson, R.P. ; Leary, C. ; Macafee, S. ; Plumb, A. ; Rykalin, V. ; Sadrozinski, H.F.-W. ; Schubert, K.-D. ; Schulte, R. ; Schultze, B. ; Steinberg, D. ; Witt, M. ; Zatserklyaniy, A.

  • Author_Institution
    Santa Cruz Inst. for Particle Phys., Univ. of California Santa Cruz, Santa Cruz, CA, USA
  • Volume
    33
  • Issue
    4
  • fYear
    2014
  • fDate
    Apr-14
  • Firstpage
    875
  • Lastpage
    881
  • Abstract
    Proton radiography has applications in patient alignment and verification procedures for proton beam radiation therapy. In this paper, we report an experiment which used 200 MeV protons to generate proton energy-loss and scattering radiographs of a hand phantom. The experiment used the first-generation proton computed tomography (CT) scanner prototype, which was installed on the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. It was found that while both radiographs displayed anatomical details of the hand phantom, the energy-loss radiograph had a noticeably higher resolution. Nonetheless, scattering radiography may yield more contrast between soft and bone tissue than energy-loss radiography, however, this requires further study. This study contributes to the optimization of the performance of the next-generation of clinical proton CT scanners. Furthermore, it demonstrates the potential of proton imaging (proton radiography and CT), which is now within reach of becoming available as a new, potentially low-dose medical imaging modality.
  • Keywords
    biomedical equipment; bone; computerised tomography; diagnostic radiography; image reconstruction; medical image processing; optimisation; orthopaedics; phantoms; bone tissue; clinical proton CT scanners; clinical proton synchrotron; energy-loss radiography; first-generation proton computed tomography scanner prototype; hand phantom; low-dose medical imaging modality; patient alignment-verification procedures; performance optimization; proton energy-loss radiography; proton imaging; prototype proton CT scanner; scattering radiographs; soft tissue; Computed tomography; Diagnostic radiography; Image reconstruction; Phantoms; Protons; Scattering; Data reduction; proton imaging; spatial resolution; tomographic reconstruction of material properties;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2013.2297278
  • Filename
    6701142