DocumentCode
459809
Title
A New Algorithm for Improved Dip/Sag Detection with Application to Improved Performance of Wind Turbine Generators
Author
Barendse, P. ; Naidoo, R. ; Douglas, H. ; Pillay, P.
Author_Institution
Dept. of Electr. Eng., Cape Town Univ., Rondebosch
Volume
1
fYear
2006
fDate
8-12 Oct. 2006
Firstpage
118
Lastpage
123
Abstract
This paper focuses on the application of a new algorithm for voltage sag/dip detection for improved protection of wind generators when subjected to power system disturbances. Improper protection of these systems during a voltage dip can introduce instability into the network. A description of the doubly-fed induction wind generator system is presented as well as a mathematical description of the detection algorithm. The performance of the algorithm is compared to other detection methods. The results show that the detection algorithm can benefit wind energy conversion systems when used as part of the fault migration system
Keywords
asynchronous generators; fault location; power supply quality; power system faults; wind turbines; doubly-fed induction wind generator system; fault migration system; power system disturbances; voltage dip detection; voltage sag detection; wind energy conversion systems; wind turbine generators; Africa; Cities and towns; Detection algorithms; Induction generators; Power generation; Power system protection; Voltage fluctuations; Wind energy; Wind energy generation; Wind turbines; Nonlinear Filter; Sag Detection; Wind Turbine Generators;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 2006. 41st IAS Annual Meeting. Conference Record of the 2006 IEEE
Conference_Location
Tampa, FL
ISSN
0197-2618
Print_ISBN
1-4244-0364-2
Electronic_ISBN
0197-2618
Type
conf
DOI
10.1109/IAS.2006.256493
Filename