Title :
Impact Factors in Measurements of Ion-Current Density Produced by High-Voltage DC Wire´s Corona
Author :
Chao Fang ; Xiang Cui ; Xiangxian Zhou ; Tiebing Lu ; Yongzan Zhen ; Xuebao Li
Author_Institution :
State Key Lab. of Alternate Electr. Power Syst. with Renewable Energy Sources, North China Electr. Power Univ., Beijing, China
Abstract :
The reduced-scale model of HVDC transmission lines in the laboratory is widely used to investigate the ionized fields. This paper is aimed at analyzing impact factors of the ion-current density measurement system based on Wilson plates in the laboratory. Both experimental and numerical simulation methods are used to obtain the characteristics of the measurement system. The results show that measurement data can be calibrated with different Wilson plates, and suitable parameters are proposed in this paper to meet the requirement of measurements. The measurement system described in this paper can be used in other similar applications.
Keywords :
HVDC power transmission; corona; density measurement; numerical analysis; power transmission lines; HVDC transmission lines; Wilson plates; high-voltage DC; ion-current density measurement system; ionized fields; numerical simulation; wire´s corona; Corona; Density measurement; HVDC transmission; Numerical models; Resistors; Transmission line measurements; Wires; HVDC power transmission lines; Wilson plate; ion-current density; reduced-scale model;
Journal_Title :
Power Delivery, IEEE Transactions on
DOI :
10.1109/TPWRD.2013.2252203