Abstract
This paper discussed four different no-electric methods for diagnosis and troubleshooting of the large power transformers, including electron microscopy, infrared thermograph (IRT), ICP plasma emission spectrum and biological technology used for oil analysis. Practice concluded that these approaches were effective in identifying the specific faults in the transformer tanks. Successful application of these approaches also showed that interdisciplinary collaboration is a good path to resolve complex technical problems on site
Keywords
electron microscopy; fault diagnosis; infrared imaging; power transformer insulation; transformer oil; ICP plasma emission spectrum; IRT; biological technology; electron microscopy; fault diagnosis; infrared thermograph; interdisciplinary collaboration; nonelectric method; oil analysis; power transformers; transformer tanks; Electron emission; Electron microscopy; Fault diagnosis; Infrared spectra; Oil insulation; Online Communities/Technical Collaboration; Petroleum; Plasma applications; Plasma diagnostics; Power transformers;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics, 2006 IEEE International Symposium on
Conference_Location
Montreal, Que.
Print_ISBN
1-4244-0496-7
Electronic_ISBN
1-4244-0497-5
Type
conf
DOI
10.1109/ISIE.2006.295839
Filename
4078514
Link To Document